🔍 Introduction to the U1000MKII-FM Ultrasonic Flow Meter
The U1000MKII-FM is a fixed, clamp-on ultrasonic flow meter designed for non-invasive flow measurement in industrial settings. Manufactured by Micronics, this device offers a cost-effective alternative to traditional in-line meters, providing accurate and reliable flow data without the need to cut into pipes or halt operations.
⚙️ Key Features and Specifications
- Measurement Technique: Ultrasonic, cross-correlation transit time method.
- Pipe Size Compatibility: Two adjustable options: 22mm–115mm and 125mm–180mm outer diameter.
- Flow Velocity Range: 0.1 m/s to 10 m/s (0.3 ft/s to 32 ft/s).
- Accuracy: ±1% to ±3% of flow reading for velocities above 0.3 m/s.
- Temperature Range: 0°C to 85°C (32°F to 185°F).
- Outputs: Integrated pulse output with optional 4-20mA and Modbus RTU slave (RS485 serial) communications.
- Installation: Simple clamp-on design requiring no specialist tools or pipe modifications.
- Display: Backlit LCD for easy reading and configuration.
- Enclosure Rating: IP54 for electronics enclosure.
🏭 Applications Across Industries
The U1000MKII-FM is versatile and suitable for various applications, including:
- Building Services: Monitoring heating and cooling systems.
- Energy Management: Tracking energy usage in HVAC systems.
- Water Treatment: Measuring flow rates in treatment processes.
- Chemical and Pharmaceutical Industries: Ensuring accurate flow in sensitive processes.
- Food and Beverage: Maintaining consistent flow in production lines.
🛠️ Installation and Operation
Installing the U1000MKII-FM is straightforward:
- Preparation: Determine the pipe’s outer diameter and material.
- Sensor Placement: Apply acoustic gel to the sensors and attach them to the pipe using the provided banding.
- Configuration: Connect the device to a 12V–24V AC/DC power supply, enter the pipe’s inner diameter, and adjust sensor positions as needed.
- Operation: Once set up, the device provides real-time flow data via its LCD and outputs.
FAQ
1. What makes the U1000MKII-FM different from traditional flow meters?
Unlike traditional meters that require cutting into pipes, the U1000MKII-FM offers a non-invasive clamp-on design, reducing installation time and maintenance costs.
2. Can the U1000MKII-FM handle different pipe materials?
Yes, it’s compatible with steel, stainless steel, plastic, and copper pipes.
3. Is the device suitable for both hot and chilled water applications?
Absolutely. It operates effectively within a temperature range of 0°C to 85°C, making it ideal for various water-based systems.
4. Does the U1000MKII-FM support integration with building management systems?
Yes, with optional Modbus RTU and 4-20mA outputs, it can integrate seamlessly with most management systems.
5. How accurate is the flow measurement?
The device offers an accuracy of ±1% to ±3% for flow velocities above 0.3 m/s, ensuring reliable data for critical applications.
The U1000MKII-FM stands out as a reliable, non-invasive solution for accurate flow measurement across various industries. Its ease of installation, compatibility with multiple pipe materials, and integration capabilities make it a valuable tool for modern flow monitoring needs.